- Features
-
Details
Features
Insulation
Seamless coating with thickness at least 1.5mm to prevent infiltration of water and moisture provides high quality insulation electrically and mechanically.
Compact and light weight
Totally isolated and compact size of ducts enable the saving of the facility space, which can lead efficient design.bearing compact and light.
Low voltage drop
The voltage drop is very low because the short distance between isolated conductors causes low reactance.
High short time current capacity
The mechanical strength to overcome the magnetic force between conductors allows the higher short time current capacity than that of standards, JIS and KS.
Ease of installation and maintenance
Small, light and one-touch joint system enable easy installation. No bolt connection required other than the standard connection. It’s also safe because all conductors are insulated.
Temperature rise
The temperature rise shall be made uniformly regardless of the bus duct arrangement - horizontal, vertical, flat and edgy-due to no convection inside.
Safe from fire
It do not cause the fire and ensure safety in case of fire because of the structure and the insulation material that is flame-retardant.
No noise
Solid structure does not make any noise that may happen by vibration due to current flow.
No influence of induction
Conductors are contacted together closely with proper insulation. Thus the leakage of the magnetic flux is too small to have influence on communication system.
No Holes in conductors
Joints are made without piercing holes of conductors.Clamping bolts do not run through the conductors in order to secure mechanical strength and electrical reliability.
Contact area
As Joint are made without piercing of conductors more contact area can be secured to rescue the resistance.
Joint by leaf spring
A spring material wider than the bus bar is used in jointing so as to ensure a constant contact pressure, which does not cause any unbalance of temperature rise and current flow.
No stress concentration
Providing very high reliability electrically and mechanically because of using high strength insulation spacers and removing piercing. holes in the conductors which may cause stress concentration at.the jointing area.
Ideal connection
To pursue the ideal connection jointing between conducts is made at the same time with that of between ducts.
Ease of installation and maintenance
One-touch joint system enable easy installation.
Checking the jointing area is possible without any interruption of the power. - Additional Information
-
Additional Information
Warranty 1 year warranty - Applications
-
- Benefits
-
- Specifications
-
- Wiring Diagram
-
- Ratings
-
Ratings
Rated voltage AC660V, DC750V less Rated current AI - Fe Type : 600A ~ 5000A CU - Fe Type : 600A ~ 6500A Rated frequency 50 / 60 Hz System configuration 1P2W, 3P3W, 3P4W 3P5W (External Type) Degree of protection Indoor Type : IP41 ~ IP42 Outdoor Type : IP55 ~ IP65 Weather - Proof : IP54 Service condition Altitude : Max 1000m Ambient temperature : -20°C to 40°C Humidity : Max 97% Applied standards KS C8450, JIS C8364, IEC 439-2, BS 5486 Type General Type, Fine resistance type - Selling Price
-